Keri-systems EP1501 Manual de usuario

Busca en linea o descarga Manual de usuario para Sensores Keri-systems EP1501. Keri Systems EP1501 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 11
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Mercury Security © 2014 EP1501 DOC 10107-0036 REV 1.07 Page 1
www.mercury-security.com
2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562)986-9105 FAX (562) 986-9205
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.
EP1501 Intelligent Controller
with Paired Reader Interface for One Physical Barrier
Installation and Specifications:
1. General:
The EP1501 intelligent controller provides decision making, event reporting and database storage for the
Mercury hardware platform. Two reader interfaces configured as paired or alternate readers provide
control for one physical barrier.
Host communication is via the on-board 10-BaseT/100Base-TX Ethernet port.
Note: For UL compliance, the Power Sourcing Equipment (PSE) such as a PoE enabled network switch
and/or PoE power injectors must be UL Listed under UL294B.
Reader port 1 can accommodate a reader that utilizes TTL (D1/D0, Clock/Data), F/2F, or 2-wire RS-485
device signaling, also provides tri-state LED control, and buzzer control (one wire LED mode only). This
port can also utilize multiple 2-wire RS-485 multi-dropped devices, such as up to two readers or up to
eight remote serial I/O devices.
Reader port 2 can accommodate a reader that utilizes TTL (D1/D0, Clock/Data), or F/2F signaling, also
provides tri-state LED control, and buzzer control (one wire LED mode only). Two Form-C contact relay
outputs may be used for door strike control or alarm signaling. The relay contacts are rated at 2 A @ 30
Vdc, dry contact configuration. Two inputs are provided that may be used for monitoring the door
contact, exit push button or alarm contact. Input circuits can be configured as unsupervised or
supervised. The EP1501 requires Power over Ethernet (PoE) or 12 Vdc for power. The EP1501 may be
mounted in a 3-gang switch box; a mounting plate is supplied with the unit, or may be mounted in an
enclosure; the supplied mounting plate has mounting holes that match the MR50 mounting footprint.
2. EP1501 Hardware:
TB1 TB2 TB3
1 1 1
12V
PoE
J3
TB5
1
TB4
1
3
4
S1
2 1
ON
S2
7 6 5 4 3 2 1
J7
J1
J4
J5
BT1
K1
J6
K2
TB1
TB5
RESET SWITCH
.15 [3.81] 2.55 [64.77] 2.55 [64.77] .15 [3.81]
.20 [5.08]
5.40 [137.16]
2.35 [59.69]
.20 [5.08]
2.75 [69.85]
TAMPER
SWITCH
CONNECTION
(J7)
ETHERNET
CONNECTOR
(J6)
PoE/12Vdc
POWER SELECTOR
JUMPER (J3)
DIP SWITCHES
STATUS LEDs CHASSIS GND
Ø .125 [Ø3.175]
6 PL
SOLDER SIDE
RELAY K1 LED
RELAY K2 LED
Vista de pagina 0
1 2 3 4 5 6 ... 10 11

Indice de contenidos

Pagina 1 - 2. EP1501 Hardware:

Mercury Security © 2014 EP1501 DOC 10107-0036 REV 1.07 Page 1 www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 90815-1755, (562)986

Pagina 2 - 3. EP1501 Wiring and Setup:

Mercury Security © 2014 EP1501 DOC 10107-0036 REV 1.07 Page 10 14. Additional Mounting Information: Sources for the optional items shown be

Pagina 3 - 6. Communication Wiring:

Mercury Security © 2014 EP1501 DOC 10107-0036 REV 1.07 Page 11 Warranty Mercury Security warrants the product is free from defects in materi

Pagina 4 - DO (GREEN LED)

Mercury Security © 2014 EP1501 DOC 10107-0036 REV 1.07 Page 2 3. EP1501 Wiring and Setup: EP1501 CONNECTIONS TB1-1 IN1 Input 1 TB1-2 IN1

Pagina 5

Mercury Security © 2014 EP1501 DOC 10107-0036 REV 1.07 Page 3 DIP Switches: The four switches on S1 DIP switch configure the opera

Pagina 6 - 8. Input Circuit Wiring:

Mercury Security © 2014 EP1501 DOC 10107-0036 REV 1.07 Page 4 7. Reader/Serial I/O Device Wiring: Reader port 1 supports TTL (D1/D0,

Pagina 7 - 10. Memory Backup Battery:

Mercury Security © 2014 EP1501 DOC 10107-0036 REV 1.07 Page 5 * Inputs on supervised F/2F readers may be unsupervised or supervised (supervi

Pagina 8 - 12. IT Security

Mercury Security © 2014 EP1501 DOC 10107-0036 REV 1.07 Page 6 Reader Port 1 - OSDP Protocol Devices (2-Wire RS-485) 8. Input Circuit Wiri

Pagina 9 - 13. Specifications:

Mercury Security © 2014 EP1501 DOC 10107-0036 REV 1.07 Page 7 TB52-CNCNCNO1NO1-C9. Relay Circuit Wiring: Two Form-C contact relays are prov

Pagina 10

Mercury Security © 2014 EP1501 DOC 10107-0036 REV 1.07 Page 8 11. Status LEDs: Power-up: All LED's OFF. Initialization: LED's 1,

Pagina 11

Mercury Security © 2014 EP1501 DOC 10107-0036 REV 1.07 Page 9 13. Specifications: The interface is for use in low voltage, Class 2 circuits

Comentarios a estos manuales

Sin comentarios