Doors.NET Reference Manual
- 322 -
l Enable Door Contact - enable/disable monitoring of the door's contact switch
l Held Open - set the amount of time a door can be held open before a held open
event is generated
Strike Control
l Strike Mode - set the behavior of the strike relay with regards to the type of door
strike installed
l Strike Timing, Maximum - set the amount of time a door strike is active - 0 to 255
seconds
l Strike Timing, ADA/DDA - set the amount of time a door strike is active for ADA
and DDA standards - 0 to 255 seconds added to the Maximum Strike Timing
REX 1 Properties
l Operating Mode - set the REXoperating mode: momentary or continuous
l Do Not Pulse Door Strike - mask the door contact switch and do not energize the
door strike; typically applied when an exit door has a crash-bar
Master/Slave (In/Out)
l Reader Function - set if this reader is a solo reader or if it is a master/slave reader
used in an In/Out door application
l Paired Reader - set if this reader is the paired reader used in an In/Out door applic-
ation
Options
l Enrollment Reader - configure this reader to be an enrollment reader; card present-
ations that generate an "Access Denied - Not In File"error message will cause the
presented card number to be entered into the cardholder menu
Monitoring
l Use This Filter - select a custom filter which controls which events are displayed,
acknowledged, or recorded (in the case of video applications)
l Global Trigger - select an event trigger that will be tested when this reader creates
an event - if the event matches the trigger, the trigger will activate
Selected Hardware Door Operations
The Selected Hardware tab displays four operation groups with manual operation com-
mands that can be applied to selected doors in the grid.
NOTE:As is typical with Windows based programs, you can select multiple, random
doors or consecutive sets of doors using the standard Windows Ctrl-Click and Shift-Click
commands.